P4DTI issue job000214

TitleNo way of controlling the poll period
Statusclosed
Priorityessential
Assigned userGareth Rees
OrganizationRavenbrook
DescriptionThere's no easy way for the administrator to control the poll period. If 10 seconds gives performance problems then there should be a way of increasing the delay.
AnalysisMake poll_period a configuration parameter (again).
How foundmanual_test
Evidence<http://www.ravenbrook.com/project/p4dt...c/2001-02-05/release-0.5.1-test-report/>, item 10.
Observed in0.5.1
Introduced in0.4.0
Created byGareth Rees
Created on2001-02-14 13:58:47
Last modified byGareth Rees
Last modified on2001-12-10 19:24:03
History2001-02-14 GDR Created.

Fixes

Change Effect Date User Description
8486 closed 2001-02-14 19:34:58 Gareth Rees Restored poll_period to configuration.